II141APage 1 of 2
N1617 Alternator
w/ Remote-Mounted Regulator
Installation Instructions
Thissymbolisusedtoindicatepresence
ofhazard(s)thatcancauseminor
propertydamage.
CAUTION
Install alternator as shown in Figure 1:
Slipbushinglocatedinrearmounting
footmustbesecurelytightenedagainst
alternatormountingbracketonengine.
Failuretodosocanresultinbroken
mountingfeetorbrokenuppermounting
bracket.
Figure1-AlternatorInstallationDetails(seepage2forB–Details)
CAUTION
1. Units are shipped with shaft collar, Belleville washer,
and nut. Remove shaft collar. Install pulley specified
by customer, washer, and nut. Torque nut to 163
Nm/ 120 lb. ft.
2. Use hardened washers between aluminum surfaces
and bolt heads and nuts. Torque mounting bolts as
shown in Figure 1.
3. All cabling, wiring or conduit must be supported
within 305 mm/12 in. of termination on alternator.
4. Choose wire gauge for B+ and B– cables capable of
handling maximum alternator output with minimum
voltage drop. See Figures 1 and 2 for proper B+ and
B– connections.
5. Install regulator as specified by customer.
6. Install battery isolator as specified by cutomer.
Lockwasher
B+ connections on alternator
Bolt,0.3750-16UNC-2Ax1.00;torqueto20Nm/15lb.ft.whensecuringB+cables.Bothpositivecablesmustbe
connectedtogetheratbatterypositivepotentialwhenalternatorisinstalledinvehicleandduringoperation.
Interconnectcableispartofvehiclecabling.
Washer
Interconnectcable
Positivecablefromvehicle
B+outputterminals
Lockwasher
Washer
Positivecablefromvehicle
Securealternatormountinglug
tovehicleusinghardware
speciedbyvehiclemanufac-
turerandtorquesufcientto
withstandweightofalternator.
Securealternatormountinglugsto
vehicleusinghardwarespecied
byvehiclemanufacturerandtorque
sufcienttowithstandweightof
alternator.
B– connections on
alternator — see Page 2
for complete wiring
Regulatorconnector