Section A: Component Description (CONT’D)
N2013 Battery Isolator Description
and Operation
N2013 battery isolator used with this charging system:
allows alternator to charge two battery banks at the
same time.
allows one battery bank to discharge without drain-
ing the other.
is rated for 14 V or 28 V DC nominal. 600 A max.
current.
operates optimally between -40ºC to 65ºC (-40ºF to
149ºF) ambient temperature.
includes voltage ripple filter connected to negative
ground.
Figure 4 – N2013 Battery Isolator
Ground bolt
Alternator connection
System #1 connection
System #2 connection
Figure 5 - Generic Wiring Schematic for Reference Only—See Vehicle Manufacturer Specications