Ce-niehoff-co N1225-1/N1237-1/N1505-1 Troubleshooting Guides Manual de usuario Pagina 6

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 8
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 5
Page 6
TG0017B
(CONT’D)
Section 3: Advanced Troubleshooting
Yes
No
Alternator is defective.
Unplug alternator-to-regulator 4-socket harness from regulator. Connect red lead from DMM to pin A in
plug. Connect black lead to pin D in plug. Does resistance read 1.8 ± 2.2 ohms?
Chart 3b No 28 V Alternator Output – Test OVCO Circuit
Yes
No
Replace existing regulator with known good regulator.
Run engine. Does OVCO trip?
Alternator is defective.
Original regulator is
defective.
Chart 3a No 14 V Alternator Output – Test OVCO Circuit
Yes
No
With red lead from DMM connected to pin A in plug, connect black lead to B– terminal. Does
resistance read OL (out of limits)?
Alternator is defective.
Chart 3 OVCO Trip – Determine 28 V or 14 V
Yes
No
28 V side tripped OVCO circuit.
Go to Chart 3b.
With meter red lead on 28 V B+ at battery and black lead on chassis ground, start engine.
Watch meter dial: Does meter read charge voltage above 29 V?
14 V side tripped OVCO circuit.
Go to Chart 3a.
Figure 6 – Alternator-to-Regulator 4-Socket Harness Plug
SOCKET CONNECTIONS
A F–
B Phase Signal AC
C B–
D 28 V B+
Yes
No
Original regulator
is defective.
Replace regulator with known good regulator.
Run engine. Does OVCO trip?
Alternator
is defective.
Yes
No
Alternator is defective.
Unplug alternator-to-regulator 4-socket harness from regulator. At receptacle on regulator, connect red lead
from DMM to pin C. Connect black lead to B– terminal. Does resistance read OL (out of limits)?
Vista de pagina 5
1 2 3 4 5 6 7 8

Comentarios a estos manuales

Sin comentarios