TG64B
Section C: Advanced Troubleshooting
A2-329 Regulator
DESCRIPTION AND OPERATION
A2-329 Regulator with OVCO is attached directly to the
outside of alternator. Regulator setpoint has flat temper-
ature compensation. Voltage setpoint is 28.0 ±1.0 V and
14.0 ±0.5.
OVCO (overvoltage cutout) will trip at any of the
following conditions:
14 V side trips at voltage higher than regulator
setpoint that exists longer than 3 seconds of reading
voltage above 16 V. OVCO feature detects overvoltage
and reacts by disabling the alternator field circuit.
This turns off alternator. OVCO circuit will reset by
either:
Restarting engine (regulator regains control of
alternator output voltage) OR
System voltage on both 14 and 28 volt batteries
falling below 11 V. OVCO will automatically reset.
28 V side trips at voltage higher than regulator
setpoint that exists longer than 3 seconds of reading
voltage above 32 V. OVCO feature detects overvoltage
and reacts by disabling the alternator field circuit.
This turns off alternator. OVCO circuit will reset by
either:
Restarting engine (regulator regains control of
alternator output voltage) OR
System voltage on both 14 and 28 volt batteries
falling below 11 V.
Troubleshooting
Shut down vehicle and restart engine. If alternator
functions normally after restart, a “no output condition
was normal response of voltage regulator to overvoltage
condition. Inspect condition of electrical system, includ-
ing loose battery cables, both positive and negative. If
battery disconnects from system, it could cause overvolt-
age condition in electrical system, causing OVCO circuit
to trip.
If you have reset alternator once, and electrical system
returns to normal charge voltage condition, there may
have been a one time, overvoltage spike that caused
OVCO circuit to trip.
If OVCO circuit repeats cutout a second time in short
succession and shuts off alternator field circuit, try third
restart. If OVCO circuit repeats cutout a third time, go to
Chart 3a or 3b, page 7.