Ce-niehoff-co C701/C701A Troubleshooting Guides Manual de usuario Pagina 3

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 8
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 2
Page 3
TG3E
Basic Troubleshooting
1. 
Check connections at B– cable, B+ cable, and
regulator harness. Check IGN, D+, and P terminal
wiring from regulator to vehicle components. Check
ignition switch for proper operation. Repair or
replace any damaged component before electrical
troubleshooting.
2. 
Connections must be clean and tight.
3. 
Repair or replace as necessary.
4. 
If batteries are discharged, recharge or replace
batteries as necessary. Electrical system cannot
be properly tested unless batteries are charged
95% or higher.
5. 
Connect red lead of DMM to alternator B+ terminal
and black lead to alternator B– terminal. Clamp
inductive ammeter on B+ cable.
6. 
Observe charge voltage.
If charge voltage is above
32 volts, immediately shut
down system. Electrical
system damage may occur if
charging system is allowed to
operate at high voltage.
Go to Table 1 at left.
If voltage is at or below regulator setpoint, let
charging system operate for several minutes to
normalize operating temperature.
7. 
Charge voltage should increase and charge amps
should decrease. If charge voltage does not increase
within ten minutes, continue to next step.
8.  is considered fully charged if charge
voltage is at regulator setpoint and charge amps
remain at lowest value for 10 minutes.
9. If  is not performing properly,
go to Chart 3, page 7.
CAUTION
SYMPTOM
ACTION
TABLE 1—System Conditions
Check: loose drive belt; low
battery state of charge.
Check: current load on system
is greater than alternator can
produce.
Check: defective wiring or poor
ground path; low regulator
setpoint.
Check: defective alternator
and/or regulator.
Check: wrong regulator.
Check: high regulator setpoint.
Check: defective regulator.
Check: alternator.
Check: broken drive belt.
Check: battery voltage at alter-
nator output terminal.
Check: defective alternator
and/or regulator.
If alternator warning light on
vehicle is ON, do not operate
vehicle until troubleshooting
resolves the condition.
Check: defective alternator or
regulator. Go to Chart 2,
page 6.
Low Voltage Output
High Voltage Output
No Voltage Output
Preliminary Check-out
Check symptoms in Table 1 and correct if necessary.
Tools and Equipment for Job
Digital Multimeter (DMM)
Ammeter (digital, inductive)
CEN Regulator Bypass Adapter A10-129
Jumper wire
Identication Record
List the following for proper troubleshooting:
Alternator model number _________________________
Regulator model number ________________________
Setpoints listed on regulator _____________________
No Air-Conditioning/
Alternator Warning
Light On
Section B: Basic Troubleshooting
CAUTION
Failure to check for the following
conditions will result in erroneous
test results in the troubleshooting
charts.
NOTICE
Vista de pagina 2
1 2 3 4 5 6 7 8

Comentarios a estos manuales

Sin comentarios